Part Number Hot Search : 
UNRL113 2809B XD2470R 1N474 TCA971 022AXA ZUY53W IR2156TR
Product Description
Full Text Search
 

To Download MC10E197FNR2 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 MC10E197 5V ECL Data Separator
The MC10E197 is an integrated data separator designed for use in high speed hard disk drive applications. With data rate capabilities of up to 50 Mb/s the device is ideally suited for today's and future state-of-the-art hard disk designs. The E197 is typically driven by a pulse detector which reads the magnetic information from the storage disk and changes it into ECL pulses. The device is capable of operating on both 2:7 and 1:7 RLL coding schemes. Note that the E197 does not do any decoding but rather prepares the disk data for decoding by another device. For applications with higher data rate needs, such as tape drive systems, the device accepts an external VCO. The frequency capability of the integrated VCO is the factor which limits the device to 50 Mb/s. A special anti-equivocation circuit has been employed to ensure timely lock-up when the arriving data and VCO edges are coincident. Unlike the majority of the devices in the ECLinPS family, the E197 is available in only 10H compatible ECL. The device is available in the standard 28-lead PLCC. Since the E197 contains both analog and digital circuitry, separate supply and ground pins have been provided to minimize noise coupling inside the device. The device can operate on either standard negative ECL supplies or, as is more common, on positive voltage supplies.
http://onsemi.com
MARKING DIAGRAM
1 28
MC10E197FN PLCC-28 CASE 776 FN SUFFIX A WL YY WW AWLYYWW
= Assembly Location = Wafer Lot = Year = Work Week
* * * * * *
2:7 and 1:7 RLL Format Compatible Fully Integrated VCO for 50 Mb/s Operation External VCO Input for Higher Operating Frequency Anti-equivocation Circuitry to Ensure PLL Lock PECL Mode Operating Range: VCC = 4.2 V to 5.7 V with VEE = 0 V NECL Mode Operating Range: VCC = 0 V with VEE = -4.2 V to -5.7 V Internal Input Pulldown Resistors
ORDERING INFORMATION
Device MC10E197FN MC10E197FNR2 Package PLCC-28 PLCC-28 Shipping 37 Units/Rail 500 Units/Reel
* * ESD Protection: > 1 KV HBM, > 75 V MM * Meets or Exceeds JEDEC Spec EIA/JESD78 IC Latchup Test * Moisture Sensitivity Level 1 * *
For Additional Information, see Application Note AND8003/D Flammability Rating: UL-94 code V-0 @ 1/8, Oxygen Index 28 to 34 Transistor Count = 483 devices
(c) Semiconductor Components Industries, LLC, 2006
June, 2006 - Rev. 6
1
Publication Order Number: MC10E197/D
MC10E197
V EEVCO 20 V CCVCO VCOIN CAP2 CAP1 V CCO0 19 18 17 16
25 TEST EXTVCO ENVCO VEE ACQ TYPE RDEN 26 27 28
1
NC 24
23
22
21
RDCLK RDCLK VCC RSDATA RSDATA PUMPUP RSETDN
LOGIC DIAGRAM AND PINOUT ASSIGNMENT
* All VCC and VCCOX pins are tied together on the die. Warning: All VCC, VCCO, and VEE pins must be externally connected to Power Supply to guarantee proper operation.
2 3 4
Pinout: 28-Lead PLCC (Top View)
15 14 13 12
5 RFFCLK
6 RFFCLK
7 RAWD
8 RAWD
9 PUMPDN
10 RSETUP
11 V CCO1
PIN DESCRIPTIONS
PIN REFCLK REFCLK RDEN RAWD VCOIN CAP1/CAP2 ENVCO EXTVCO ACQ TYPE TEST PUMPUP PUMPDN RSETUP RSETDN RDATA RDCLK VCC, VCCOX, VCCVCO VEE, VEEVCO FUNCTION ECL Reference clock equivalent to one clock cycle per decoding window. ECL Reference clock equivalent to one clock cycle per decoding window. ECL Enable data synchronizer when HIGH. When LOW enable the phase/frequency detector steered by REFCLK. ECL Data Input to Synchronizer logic. ECL VCO control voltage input ECL VCO frequency controlling capacitor inputs ECL VCO select pin. LOW selects the internal VCO and HIGH selects the external VCO input. Pin floats LOW when left open. ECL External VCO pin selected when ENVCO is HIGH ECL Acquisition circuitry select pin. This pin must be driven HIGH at the end of the data sync field for some sync field types. ECL Selects between the two types of commonly used sync fields. When LOW it selects a sync field interspersed with 3 zeroes (2:7 RLL code). When HIGH it selects a sync field interspersed with 2 zeroes (1:7 RLL code). ECL Input included to initialize the clock flip-flop for test purposes only. Pin should be left open (LOW) in actual application. ECL Open collector charge pump output for the signal pump ECL Open collector charge pump output for the reference pump ECL Current setting resistor for the signal pump ECL Current setting resistor for the reference pump ECL Synchronized data output ECL Synchronized clock output Most positive supply rails. Digital and analog supplies are independent on chip Most negative supply rails. Digital and analog supplies are independent on chip RDEN
LOGIC DIAGRAM
REFCLK CAP1 CAP2 VCOIN EXTVCO ENVCO RAWD ACQ TYPE INTERNAL VCO VCO MUX DATA PHASE DETECTOR PHASE FREQUENCY DETECTOR CHARGE PUMP CURRENTSOURCES PUMPUP PUMPDN RSETUP RSETDN RDATA RDCLK
PHASE DETECTOR MUX
ACQUISITION CIRCUITRY
CLOCK & DATA BUFFER
http://onsemi.com
2
MC10E197
MAXIMUM RATINGS (Note 1)
Symbol VCC VEE VI Iout TA Tstg JA JC VEE Tsol Parameter PECL Mode Power Supply NECL Mode Power Supply PECL Mode Input Voltage NECL Mode Input Voltage Output Current Operating Temperature Range Storage Temperature Range Thermal Resistance (Junction to Ambient) Thermal Resistance (Junction to Case) PECL Operating Range NECL Operating Range Wave Solder <2 to 3 sec @ 248C 1. Maximum Ratings are those values beyond which device damage may occur. 0 LFPM 500 LFPM std bd 28 PLCC 28 PLCC 28 PLCC Condition 1 VEE = 0 V VCC = 0 V VEE = 0 V VCC = 0 V Continuous Surge VI VCC VI VEE Condition 2 Rating 8 -8 6 -6 50 100 0 to +85 -65 to +150 63.5 43.5 22 to 26 4.2 to 5.7 -5.7 to -4.2 265 Units V V V V mA mA C C C/W C/W C/W V V C
10E SERIES PECL DC CHARACTERISTICS VCCx= 5.0 V; VEE= 0.0 V (Note 1)
0C Symbol IEE VOH VOL VIH VIL IIH IIL Characteristic Power Supply Current Output HIGH Voltage (Note 2) Output LOW Voltage (Note 2) Input HIGH Voltage Input LOW Voltage Input HIGH Current Input LOW Current 0.5 0.3 Min 90 3980 3050 3830 3050 Typ 150 4070 3210 3995 3285 Max 180 4160 3370 4160 3520 150 0.5 0.25 Min 90 4020 3050 3870 3050 25C Typ 150 4105 3210 4030 3285 Max 180 4190 3370 4190 3520 150 0.3 0.2 Min 90 4090 3050 3940 3050 85C Typ 150 4185 3227 4110 3302 Max 180 4280 3405 4280 3555 150 Unit mA mV mV mV mV A A
NOTE: Devices are designed to meet the DC specifications shown in the above table, after thermal equilibrium has been established. The circuit is in a test socket or mounted on a printed circuit board and transverse air flow greater than 500 lfpm is maintained. 1. Input and output parameters vary 1:1 with VCC. VEE can vary +0.46 V / -0.06 V. 2. Outputs are terminated through a 50 ohm resistor to VCC-2 volts.
10E SERIES NECL DC CHARACTERISTICS VCCx= 0.0 V; VEE= -5.0 V (Note 1)
0C Symbol IEE VOH VOL VIH VIL IIH IIL Characteristic Power Supply Current Output HIGH Voltage (Note 2) Output LOW Voltage (Note 2) Input HIGH Voltage Input LOW Voltage Input HIGH Current Input LOW Current 0.5 0.3 Min 90 -1020 -1950 -1170 -1950 Typ 150 -930 -1790 -1005 -1715 Max 180 -840 -1630 -840 -1480 150 0.5 0.065 Min 90 -980 -1950 -1130 -1950 25C Typ 150 -895 -1790 -970 -1715 Max 180 -810 -1630 -810 -1480 150 0.3 0.2 Min 90 -910 -1950 -1060 -1950 85C Typ 150 -815 -1773 -890 -1698 Max 180 -720 -1595 -720 -1445 150 Unit mA mV mV mV mV A A
NOTE: Devices are designed to meet the DC specifications shown in the above table, after thermal equilibrium has been established. The circuit is in a test socket or mounted on a printed circuit board and transverse air flow greater than 500 lfpm is maintained. 1. Input and output parameters vary 1:1 with VCC. VEE can vary +0.46 V / -0.06 V. 2. Outputs are terminated through a 50 ohm resistor to VCC-2 volts.
http://onsemi.com
3
MC10E197
AC CHARACTERISTICS VCCx= 5.0 V; VEE= 0.0 V or VCCx= 0.0 V; VEE= -5.0 V (Note 1)
0C Symbol fVCO Characteristic Frequency of the VCO (Note 5) Tuning Ratio (Note 6) ts tH tSKEW Time from RDATA Valid to Rising Edge of RDCLK (Notes 4) Time from Rising Edge of RDCLK to RDATA invalid (Notes 4) Skew Between RDATA and RDATA Min 150 1.53 TVCO - 550 TVCO 300 1.87 Typ Max Min 150 1.53 TVCO - 500 TVCO 300 1.87 25C Typ Max Min 150 1.53 TVCO - 500 TVCO 300 1.87 ps ps ps 85C Typ Max Unit MHz
tJITTER Cycle-to-Cycle Jitter TBD TBD TBD ps 1. VEE can vary +0.46 V / -0.06 V 1 Applies to the input current for each input except VCOIN 2 For a nominal set current of 3.72 mA, the resistor values for RSETUP and RSETDN should be 130(0.1%). Assuming no variation between these two resistors, the current match between the PUMPUP and PUMPDN output signals should be within 3%. ISET is calculated as (VEE+ 1.3v - VBE)/R; where R is RSETUP or RSETDN and a nominal value for VBE is 0.85 volts. 3 Output leakage current of the PUMPUP or PUMPDN output signals when at a LOW level. 4 TVCO is the period of the VCO. 5 The VCO frequency determined with VCOIN = VEE + 0.5 volts and using a 10pF tuning capacitor. 6 The tuning ratio is defined as the ratio of fVCOMAX to FVCOMIN where fVCOMAX is measured at VCOIN = 1.3 V + VEE and fVCOMAX is measured at VCOIN = 2.6 V + VEE
RDATA
RDATA RDCLK
tS
tH
RDCLK
SETUP AND HOLD TIMING DIAGRAMS
http://onsemi.com
4
MC10E197
APPLICATIONS INFORMATION
General Operation
Operation The E197 is a phase-locked loop circuit consisting of an internal VCO, a Data Phase detector with associated acquisition circuitry, and a Phase/Frequency detector (Figure 1). In addition, an enable pin(ENVCO) is provided to disable the internal VCO and enable the external VCO input. Hence, the user has the option of supplying the VCO signal. The E197 contains two phase detectors: a data phase detector for synchronizing to the non-periodic pulses in the read data stream during the data read mode of operation, and a phase/ frequency detector for frequency (and phase) locking to an external reference clock during the "idle" mode of operation. The read enable (RDEN) pin muxes between these two detectors.
Data Read Mode
The data pins (RAWD) are enabled when the RDEN pin is placed at a logic high level, thus enabling the Data Phase detector (Figure1) and initiating the data read mode. In this mode, the loop is servoed by the timing information taken from the positive edges of the input data pulses. This phase detector samples positive edges from the RAWD signal and generates both a pump up and pump down pulse from any edge of the input data pulse. The leading edge of the pump up pulse is time modulated by the leading edge of the data signal, whereas the rising edge of the pump up pulse is generated synchronous to the VCO clock. The falling edge of the pump down pulse is synchronous to the falling edge of the VCO clock and the rising edge of the pump down signal is synchronous to the rising edge of the VCO clock. Since both edges of the VCO are used the internal clock a duty cycle of 50%. This pulse width modulation technique is used to generate the servoing signal which drives the VCO. The pump down signal is a reference pulse which is included to provide an evenly balanced differential system, thereby allowing the synthesis of a VCO input control signal after appropriate signal processing by the loop filter. By using suitable external filter circuitry, a control signal for input into the VCO can be generated by inverting the pump down signal, summing the inverted signal with the pump up signal and averaging the result. The polarity of this control signal is defined as zero when the data edges lead the clock by a half clock cycle. If the data edges are advanced with respect to the zero polarity data/VCO edge relationship, the control signal is defined to have a negative polarity; whereas if the VCO is advanced with respect to the zero polarity data/VCO edge relationship, the control signal is defined to have a positive polarity. If there is no data edge present at the RAWD input, the corresponding pump up and pump down outputs are not generated and the resulting control output is zero.
Acquisition Circuitry
data. For the case in which lock-up is attempted when the data edges are coincident with the VCO edges, the pump down signal may enter an indeterminate state for an unacceptably long period due to the violation of internal set up and hold times. After an initial pump down pulse, the circuit blocks successive pump down pulses, and inserts extra pump up pulses, during portions of the sync field that are known to contain zeros. Thus, the data phase detector is forced to have a nonzero output during the lock-up period, and the restoring force ensures correction of the loop within an acceptable time. Hence, this circuitry provides a quasi-deterministic pump down output signal, under the condition of coincident data and VCO edges, allowing lock-up to occur with excessive delays. The ACQ line is provided to disable (disable = HIGH) the acquisition circuit during the data portion of a sector block. Typically, this circuit is enabled at the beginning of the sync field by a one-shot timer to ensure a timely lock-up. The TYPE line allows the choice between two sync field preamble types; transitions interspersed with two zeros between transitions. These types of sync fields are used with the 1:7 and 2:7 coding schemes, respectively.
Idle Mode
The acquisition circuitry is provided to assist the data phase detector in phase locking to the sync field that precedes the
In the absence of data or when the drive is writing to the disk, PLL servoing is accomplished by pulling the read enable line (RDEN) low and providing a reference clock via the REFCLK pins. The condition whereby RDEN is low selects the Phase/Frequency detector (Figure 1) and the 10E197 is said to be operating in the "idle mode". In order to function as a frequency detector the input waveform must be periodic. The pump up and pump down pulses from the Phase/Frequency detector will have the same frequency, phase and pulse width only when the two clocks that are being compared have their positive edges aligned and are of the same frequency. As with the data phase detector, by using suitable external filter circuitry, a VCO input control signal can be generated by inverting the pump down signal, summing the inverted signal with the pump up signal and averaging the result. The polarity of this control signal is defined as zero when all positive edges of both clocks are coincident. For the case in which the frequencies of the two clocks are the same but the clock edges of the reference clock are slightly advanced with respect to the VCO clock, the control clock is defined to have a positive polarity. A control signal with negative polarity occurs when the edges of the reference clock are delayed with respect to those of the VCO. If the frequencies of the two clocks are different, the clock with the most edges per unit time will initiate the most pulses and the polarity of the detector will reflect the frequency error. Thus, when the reference clock is high in frequency than the VCO clock the polarity of the control signal is positive; whereas a control signal with negative polarity occurs when the frequency of the reference clock is lower than the VCO clock.
http://onsemi.com
5
MC10E197
Phase-Lock Loop Theory
Introduction Phase lock loop (PLL) circuits are fundamentally feedback systems used to synchronize the frequency of an oscillator to an incoming signal. In addition to frequency synchronization, the PLL circuitry is designed to minimize the phase difference between the system input and output signals. A block diagram of a feedback control system is shown in Figure 1. where: A(s) is the product of the feed-forward transfer functions.
+
Gain Constants As mentioned, each of the three sections in the phase lock loop block diagram has an associated open loop gain constant. Further, the gain constant of the filter circuitry is composed of the product of three gain constants, one for each filter subsection. The open loop gain constant of the feed-forward path is given by
Kol = K * Ko * K1 * Kl * Kd eqt. 1
and obtained by performing a root locus analysis.
Phase Detector Gain Constant
Xi(s)
R
Xe(s)
-
A(s)
Xo(s)
(s)
The gain of the phase detector is a function of the operating mode and the data pattern. The 10E197 provides data separation for signals encoded in 2:7 or 1:7 RLL encoding schemes; hence, Tables 1 and 2 are coding tables for these schemes. Table 3 lists nominal phase detector gains for both 2:7 and 1:7 sync fields.
NRZ Data Sequence 00 01 100 101 111 1100 1101 1000 0100 001000 100100 000100 00001000 00100100 Code Sequence
Figure 1. Feedback System
(s) is the product of the feedback transfer functions. The transfer function for this closed loop system is
Xo(s) Xi(s) = A(s) 1 + A(s)(s)
Typically, phase lock loops are modeled as feedback systems connected in a unity feedback configuration ((s)=1) with a phase detector, a VCO (voltage controlled oscillator), and a loop filter in the feed-forward path, A(s). Figure 2 illustrates a phase lock loop as a feedback control system in block diagram form.
Fi PHASE DETECTOR Kf LOOP FILTER F(s)
VCO
Table 1. 2:7 RLL Encoding Table
NRZ Data Sequence 00 01 10 1100 1101 1110 1111 X01 010 X00 010001 X00000 X00001 010000 Code Sequence
Ko s
Fo
Figure 2. Phase Lock Loop Block Diagram
The closed loop transfer function is:
Xo(s) Xi(s) where: K= Ko= =
An X in the leading bit of a code sequence is assigned the complement of the bit Table 2. 1:7 RLL Encoding Table
Sync Pattern 2:7 1:7 Read Mode 121 mV/radian 161 mV/radian Idle Mode 484 mV/radian 483 mV/radian
K Ko F(s) s 1 + K Ko F(s) s
the phase detector gain. the VCO gain. Since the VCO introduces a pole at the origin of the s-plane, Ko is divided by s. F(s) = the transfer function of the loop filter.
Table 3. Phase Detector Gain Constants VCO Gain Constant
The gain of the VCO is a function of the tuning capacitor. For a value of 10 pF a nominal value of the gain, Ko, is 20 MHz per volt.
The 10E197 is designed to implement the phase detector and VCO functions in a unity feedback loop, while allowing the user to select the desired filter function.
http://onsemi.com
6
MC10E197
Filter Circuitry Gain Constant(s)
The open loop gain constant of the filter circuitry is given by:
Kfc = K1 * Kl * Kd eqt. 2
The transfer function and the element values for the loop filter are derived by dividing the filter into three cascaded subsections: filter input, augmenting integrator, and the voltage divider network (Figure 4). Loop Filter Transfer Function The open loop transfer function of the phase lock loop is the product of each individual filter subsection, as well as the phase detector and VCO. Thus, the open loop filter transfer function is:
Fo(s) = K * Ko * F1(s) * Fl(s) * Fd(s) s where: F1(s) = K1 * 1 * (s + p1) 1 s 1 [s2 + (2 o1) s + 2 ] o1 (s + z) [s2 + (2o2 ) s + 2o2]
The individual gain constants are defined in the appropriate subsections of this document. Loop Filter The two major functions of the loop filter are to remove any noise or high frequency components present in the phase detector output signal and, more importantly, to control the characteristics which determine the dynamic response of the phase lock loop; i.e. capture range, loop bandwidth, capture time, and transient response. Although a variety of loop filter configurations exist, this section will only describe a filter capable of performing the signal processing as described in the Data Read Mode and the Idle Mode sections. The loop filter consists of a differential summing amplifier cascaded with an augmenting integrator which drives the VCOIN input to the 10E197 through a resistor divider network (Figure 3).
R1 PUMPUP CIN MC34182 VEEVCO PUMPDN R1 CIN VEEVCO R1 RIA
Fl(s) = Kl *
*
Fd(s) = Kd *
1 (s + p2)
RA
CA
RV MC34182 RO R3 VCCVCO R1 VCCVCO VEEVCO VEEVCO DB CO VO
Figure 3. Loop Filter Circuitry
R1
FILTER INPUT F1(s) AUGMENTING INTEGRATOR FI(s) VOLTAGE DIVIDER FO(s)
R1
Fi(s)
F(s)=F1(s)Fi(s)Fd(s)
IPUMPUP VEEVCO VEEVCO
MC34182
Figure 4. Loop Filter Block Diagram
A root locus analysis is performed on the open loop transfer function to determine the final pole-zero locations and the open loop gain constant for the phase lock loop. Note that the open loop gain constant impacts the crossover frequency and that a lower frequency crossover point means a much more efficient filter. Once these positions and constants are determined the component values may be calculated.
R1 IPUMPDN VEEVCO CIN VEEVCO R1 VCCVCO
V01
Figure 5. Filter Input Subsection
http://onsemi.com
7
MC10E197
Filter Input The primary function of the filter input subsection is to convert the output of the phase detector into a single ended signal for subsequent processing by the integrator circuitry. This subsection consists of the 10E197 charge pump current sinks, two shunt capacitors, and a differential summing amplifier (Figure 5). Hence, this portion of the filter circuit contributes a real pole and two complex poles to the overall loop transfer function F(s). Before these pole locations are selected, appropriate values for the current setting resistors (RSETUP and RSETDN) must be ascertained. The goal in choosing these resistor values is to maximize the gain of the filter input subsection while ensuring the charge pump output transistors operate in the active mode. The filter input gain is maximized for a charge pump current of 1.1 mA; a value of 464 for both RSETUP and RSETDN yields a nominal charge pump current of 1.1 mA. It should be noted that a dual bandwidth implementation of the phase lock loop may be achieved by modifying the current setting resistors such that an electronic switch enables one of two resistor configurations. Figure 6 shows a circuit configuration capable of providing this dual bandwidth function. Analysis of the filter input circuitry yields the transfer function:
F1(s) = K1 * 1 * (s + p1) 1 CIN 1 [s2 + (2 o1) s + 2 ] o1
The second order pole set arises from the two pole model for an op-amp. The open loop gain and the first open loop pole for the op-amp are obtained from the data sheets. Typically, op-amp manufacturers do not provide information on the location of the second open loop pole; however, it can be approximated by measuring the roll off of the op-amp in the open loop configuration. The second pole is located where the gain begins to decrease at a rate of 40 dB per decade. The inclusion of both poles in the differential summing amplifier transfer function becomes important when closing the feedback path around the op-amp because the poles migrate; and this migration must be accounted for to accurately determine the phase lock loop transient performance. Typically the op-amp poles can be approximated by a pole pair occurring as a complex conjugate pair making an angle of 45 to the real axis of the complex frequency plane. Two constraints on the selection of the op-amp pole pair are that the poles lie beyond the crossover frequency and they are positioned for near unity gain operation. Performing a root locus analysis on the op-amp open loop configuration and adhering to the two constraints yields the pole positions contributed by the op-amp.
Determination of Element Values
The gain constant is defined as: K1 = A1 * where: A1= op-amp gain constant for the selected pole positions. CIN = phase detector shunt capacitor. eqt. 3
Since the difference amplifier is configured to operate as a differential summer the resistor values associated with the amplifier are of equal value. Further, the typical input resistance to the summing amplifier is 1 k; thus, the op-amp resistors are set at 1 k. Having set the input resistance to the op-amp and selected the position of the real pole, the value of the shunt capacitors is determined using the following relationship:
p1 = 1 2R1CIN eqt. 4
The real pole is a function of the input resistance to the op-amp and the shunt capacitors connected to the phase detector output. For stability the real pole must be placed beyond the unity gain frequency; hence, this pole is typically placed midway between the unity crossover and phase detector sampling frequency, which should be about ten times greater.
RSETUP 464 464 464 RSETDN 464
Augmenting Integrator The augmenting integrator consists of an active filter with a lag-lead network in the feedback path (Figure 7).
RIA VIN RA CA
MC34182 VO2 VEEVCO RIA VCCVCO ELECTRONIC SWITCH
Figure 7. Integrator Subsection
VEEVCO
Figure 6. Dual Bandwidth Current Source Implementation
http://onsemi.com
8
MC10E197
Analysis of this portion of the filter circuit yields the transfer function:
F1(s) = Kl * 1 s * (s + z) [s2 + (2 o2 s + 2 o2 ) ]
The gain constant is defined as: RA Kl = Al * RlA where: Al =
Voltage Divider The input range to the VCOIN input is from 1.3 V + VEE to 2.6 V + VEE; hence, the output from the augmenting amplifier section must be attenuated to meet the VCOIN constraints. A simple voltage divider network provides the necessary attenuation (Figure 8).
RV VIN RO
eqt. 5
op-amp gain constant for selected pole positions.
DB
Cd
VO
RA = integrator feedback resistor.
The integrator circuit introduces a zero, a pole at the origin, and a second order pole set as described by the two pole model for an op-amp. As in the case of the differential summing amplifier, we assume the op-amp pole pair occur as a complex conjugate pair making an angle of 45 to the real axis of the complex frequency plane; are positioned for near unity gain operation; and are located beyond the crossover frequency. Since both the summing and integrating op-amps are realized by the same type of op-amp (MC34182D), the open loop pole positions for both amplifiers will be the same. Further, the loop transfer function contains two poles located at the origin, one introduced by the integrator and the other by the VCO; hence a zero is necessary to compensate for the phase shift produced by these poles and ensure loop stability. The op-amp will be stable if the crossover point occurs before the transfer function phase angle becomes 180. The zero should be positioned much less than one decade before the unity gain frequency. As in the case of the filter input circuitry, the poles and zero from this analysis will be used as open loop poles and a zero when performing the root locus analysis for the complete system.
Determination of Element Values
RlA = integrator input resistor.
Figure 8. Voltage Divider Subsection
In addition, a shunt filter capacitor connected between the VCOIN input pin and VEE provides the voltage divider subsection with a single time constant transfer function that adds a pole to the overall loop filter. The transfer function for the voltage divider network is:
Fd(s) = Kd * 1 (s + p2)
The gain constant, Kd, is defined as: Kd = 1 Rv Cd
eqt. 9
he value of Kd is easily extracted by rearranging Equation 1:
Kd =
Kol K * Ko * K1 * Kl
eqt. 10
The location of the zero is used to determine the element values for the augmenting integrator. The value of the capacitor, CA, is selected to provide adequate charge storage when the loop is not sampling data. A value of 0.1 F is sufficient for most applications; this value may be increased when the RDCLK frequency is much lower than 4 MHz. The value of RA is governed by:
z = 1 2RACA eqt. 6
The gain constant Kd is set such that the output from the integrator circuit is within the range 1.3 V +VEE to 2.6 V +VEE. The pole for the voltage divider network should be positioned an octave beyond that for the filter input. Determination of Element Values Once the pole location and the gain constant Kd are established the resistor values for the voltage divider network are determined using the design guidelines mentioned above and from the following relationship:
Kd 2 p2 = Ro Ro + Rv
For unity gain operation of the integrating op-amp the value of RlA is selected such that:
RlA = RA eqt. 7
Having determined the resistor values, the filter capacitor is calculated by rearranging Equation 9:
Cd = 1 Rv Kd
eqt. 9a
It should be noted that although the zero can be tuned by varying either RA or CA, caution must be exercised when adjusting the zero by varying CA because the integrator gain is also a function of CA. Further, the gain of the loop filter can be adjusted by changing the integrator input resistor RlA.
Finally, a bias diode is included in the voltage divider network to provide temperature compensation. The finite resistance of this diode is neglected for these calculations.
http://onsemi.com
9
MC10E197
Calculations For a 2:7 Coding Scheme
Introduction The circuit component values are calculated for a 2:7 coding scheme employing a data rate of 23 Mbit/sec. Since the number of bits is doubled when the data is encoded, the data clock is at half the frequency of the RDCLK signal. Thus, the operating frequency for these calculations is 46 MHz. Further, the pole and zero positions are a function of the data rate; hence, the component values derived by these calculations must be scaled if a different operating frequency is used. Finally, it should be noted that the values are optimized for settling time. The analysis is divided into three parts: static pole positioning, dynamic pole positioning, and dynamic zero positioning. Dynamic poles and zeros are those which the designer may position, to yield the desired dynamic response, through the judicious choice of element values. Static poles are not directly controlled by the choice of component values. Static Poles Each op-amp introduces a pair of "static" complex conjugate poles which must lie beyond the crossover frequency. As obtained from the data sheets and laboratory measurements, the two open loop poles for the MC34182D are:
P*1a = - 0.1Hz P*1b = -11.2Hz
The voltage divider pole is set approximately one octave higher than the filter input pole. Thus the open loop voltage divider pole position is picked to be:
P*2 = - 2.57MHz
Dynamic Zero Finally, the zero is positioned much less than one decade before the crossover frequency; for this design the zero is placed at:
z = - 311Hz
Once the dynamic pole and zero positions have been determined, the phase margin is determined using a Bode plot; if the phase margin is not sufficient, the dynamic poles may be moved to improve the phase margin. Finally, a root locus analysis is performed to obtain the optimum closed loop pole positions for the dynamic characteristics of interest. Component Values Having determined the closed loop pole and zero positions the component values are calculated. From the root locus analysis the dynamic pole and zero positions are:
P1 = - 573kHz P2 = - 3.06MHz z = - 311Hz
Performing a root locus analysis and following the two guidelines previously stated, an acceptable pole set is:
P1a = - 5.65 + j5.65MHz P1b = - 5.65 - j5.65MHz
Filter Input Subsection Rearranging Equation 4:
CIN = 1 2 R1 p1
Both op-amps introduce a set of static complex conjugate poles at these positions for a total of four poles. Further, the loop gain for each op-amp associated with these pole positions is determined from the root locus analysis to be:
A1 = A2 = 2.48 e15 V V
and substituting 573 kHz for the pole position and 1 k for the resistor value yields:
CIN = 278 pF
Augmenting Integrator Subsection Rearranging Equation 6:
RA = 1 2 z CA
In addition to the op-amps, the integrator and the VCO each contribute a static pole at the origin. Thus, there are a total of six static poles. Dynamic Poles The filter input and the voltage divider sections each contribute a dynamic pole. As stated previously, the filter input pole should be positioned midway between the unity crossover point and the phase detector sampling frequency. Hence, the open loop filter input pole position is selected as:
P*1 = -1.24MHz
and substituting 311 Hz for the zero position and 0.1 F for the capacitor value yields:
RA = 5.11k
From Equation 7 the value for the other resistors associated with the integrator op-amp are set equal to RA:
RlA = RA = 5.11k
http://onsemi.com
10
MC10E197
Voltage Divider Subsection The element values for the voltage divider network are calculated using the relationships presented in Equations 8, 9, and 10 with the constraint that this divider network must produce a voltage that lies within the range 1.3 V + VEE to 2.6 V + VEE. Restating Equation 9,
Kol Kd = K * Ko * K1 * Kl
the capacitor value, Cd is:
Cd = 98pF
Note that the voltage divider section can be used to set the gain, but the designer is cautioned to be sure the input value to VCOIN is within the correct range. Component Scaling As mentioned, these design equations were developed for a data rate of 23 Mbit/sec. If the data rate is different from the nominal design value the reactive elements must be scaled accordingly. The following equations are provided to facilitate scaling and were derived with the assumptions that a 2:7 coding scheme is used and that the RDCLK signal is twice the frequency of the data clock.
CIN = 278 * 46 f (pF) (pF)
eqt. 11
From the root locus analysis Kol is determined to be:
Kol = 1.585 e51 V mA sec3
From Equation 3
K1 = A1 * 1 CIN
Cd = 98 *
46 f
eqt. 12
and the gain constant K1 is:
V K1 = 8.90 e21 mA sec
where f is the RDCLK frequency in MHz. Example for an 11 Mbit/sec Data Rate As an example of scaling, assume the given filter and a 2:7 code are used but the data rate is 11 Mbit/sec. The dynamic pole positions, and therefore the bandwidth of the loop filter, are a function of the data rate. Thus a slower data rate will force the dynamic poles and the bandwidth to move to a lower frequency. From Equation 11 the value of CIN is:
CIN = 581pF
From Equation 5
Kl = Al * RA RlA
and the gain constant Kl is:
Kl = 2.48 e15 V V
and from Equation 12 the value of Cd is:
Cd = 205pF
Having determined the gain constant Kd , the value of Rv, is selected such that the constraints Rv > Ro and:
Kd 2 p2 = Ro Ro + Rv
Thus the element values for the filter are: Filter Input Subsection:
CIN = 581pF R1 = 1k
are fulfilled. The pole position P2 is determined from the root locus analysis to be:
P2 = - 3.06MHz
Integrator Subsection:
CA = 0.1F RA = 5.11k RlA = 5.11k
Hence, Rv is selected to be:
Rv = 2.15k
Voltage Divider Subsection:
Cd = 205pF Rv = 2.15k Ro = 700k
and Ro is calculated to be:
Ro = 700
Finally, using Equation 8a:
Cd = 1 Rv Kd eqt. 8a
Note, the poles P1 and P2 are now located at:
P1 = - 274kHz P2 = -1.47MHz http://onsemi.com
11
MC10E197
And, the open loop filter unity crossover point is at 300 kHz. The gain can be adjusted by changing the value of RlA and the value of Cd. Varying the gain by changing Cd is not recommended because this will also move the poles, hence affect the dynamic 2 performance of the filter.
Calculations For a 1:7 Coding Scheme
Introduction The circuit component values are calculated for a 1:7 coding scheme employing a data rate of 20 Mbit/sec. Since the number of bits increases from two to three when the data is encoded, the data clock is at two-thirds the frequency of the RDCLK signal. Thus, the operating frequency for these calculations is 30 MHz. As in the case of the 2:7 coding scheme the pole and zero positions are a function of the data rate, hence the component values derived by these calculations must be scaled if a different operating frequency is used. Again, the analysis is divided into three parts: static pole positioning, dynamic pole positioning, and dynamic zero positioning. Static Poles As in the 2:7 coding example, an MC34182D op-amp is employed, hence the pole set is:
P1a = - 5.65 + j5.65MHz P1b = - 5.65 - j5.65MHz
Once the dynamic pole and zero positions have been determined, the phase margin is determined using a Bode plot; if the phase margin is not sufficient, the dynamic poles may be moved to improve the phase margin. Finally, a root locus analysis is performed to obtain the optimum closed loop pole positions for the dynamic characteristics of interest. Component Values Having determined the closed loop pole and zero positions the component values are calculated. From the root locus analysis the dynamic pole and zero positions are:
P1 = - 541kHz P2 = - 2.73MHz z = - 311Hz
Filter Input Subsection Rearranging Equation 4
CIN = 1
2 R1 p1
and the open loop gain is:
V Al = A2 = 2.48 e15 V
and substituting 541 kHz for the pole position and 1.0 k for the resistor value yields:
CIN = 294 pF
Since the op-amps introduce a set of complex conjugate poles, a total of four poles are introduced by the op-amp. In addition, the integrator and the VCO each contribute a pole at the origin for a total of six static poles. Dynamic Poles The filter input and the voltage divider sections each contribute a dynamic pole. As stated previously, the filter input pole should be positioned midway between the unity crossover point and the phase detector sampling frequency. Hence, the open loop filter input pole position is selected as:
P*
1
Augmenting Integrator Subsection Rearranging Equation 6
RA = 1 2 z CA
and substituting 311 Hz for the zero position and 0.1 F for the capacitor value yields:
RA = 5.11k
= -1.1MHz
From Equation 7 the value for the other resistors associated with the integrator op-amp are set equal to RA:
RlA = RA = 5.11k
The voltage divider pole is set approximately one octave higher than the filter input pole. Thus, the open loop voltage divider pole position is selected as:
P*2 = - 2.28MHz
Dynamic Zero Finally, the zero is positioned much less than one decade before the crossover frequency; for this design the zero is placed at:
z = - 311Hz
Voltage Divider Subsection The element values for the voltage divider network are calculated using the relationships presented in Equations 8, 9, and 10 with the constraint that this divider network must produce a voltage that lies within the range 1.3 V + VEE to 2.6 V + VEE. Restating Equation 9,
http://onsemi.com
12
MC10E197
Kd = Kol K * Ko * K1 * Kl
From the root locus analysis Kol is determined to be:
Kol = 1.258 e51 V
MA SEC3
From Equation 3:
K1 = A1 * 1 CIN
Component Scaling As mentioned, these design equations were developed for a data rate of 20 Mbit/sec. If the data rate is different from the nominal design value the reactive elements must be scaled accordingly. The following equations provided are to facilitate scaling and were derived with the assumptions that a 1:7 coding scheme is used and that the RDCLK signal is twice the frequency of the data clock:
CIN = 294 * Cd = 156 * 30 f 30 f (pF) (pF) eqt. 13 eqt. 14
and the gain constant K1:
K1 = 8.42 e21 V mA sec
where f is the RDCLK frequency in MHz. Example for an 10 Mbit/sec Data Rate As an example of scaling, assume the given filter and a 1:7 code are used but the data rate is 10 Mbit/sec. The dynamic pole positions and, therefore, the bandwidth of the loop filter, are a function of the data rate. Thus, a slower data rate will force the dynamic poles and the bandwidth to move to a lower frequency. From Equation 13 the value of CIN is:
From Equation 5:
Kl = Al * RA RlA
and the gain constant Kl is:
Kl = 2.48 e15 V V
CIN = 588pF
and from Equation 14 the value of Cd is:
Cd = 312pF
Kd = 2.98 e6 sec -1
Having determined the gain constant Kd , the value of Rv, is selected such that the constraints Rv > Ro and:
Kd 2p2 = Ro Ro + Rv
Thus, the element values for the filter are: Filter Input Subsection:
CIN = 588pF R1 = 1.0k
are fulfilled. The pole position P2 is determined from the root locus analysis to be:
P2 = - 2.73MHz
Integrator Subsection:
CA = 0.1F RA = 5.11k RlA = 5.11k
Hence, Rv is selected to be:
Rv = 2.15k
Voltage Divider Subsection:
Cd = 312pF Rv = 2.15k Ro = 453k eqt. 8a
and Ro is calculated to be:
Ro = 453
Finally, using Equation 8a:
Cd = 1 Rv Kd
Note, the poles P1 and P2 are now located at:
P1 = - 271kHz P2 = -1.36MHz
the capacitor value, Cd is calculated to be:
Cd = 156pF
Again, note the voltage divider section can be used to set the gain, but the designer is cautioned to be sure the input value to VCOIN is within the correct range.
And, the open loop filter unity crossover point is at 300 kHz. As in the case of the 2:7 coding scheme, the gain can be adjusted by changing the value of RlA and the value of Cd. Varying the gain by changing Cd is not recommended because this will also move the poles, hence affect the dynamic performance of the filter.
http://onsemi.com
13
MC10E197
Q Driver Device Q 50 W 50 W
D Receiver Device D
V TT VTT = VCC - 2.0 V
Figure 9. Typical Termination for Output Driver and Device Evaluation (See Application Note AND8020 - Termination of ECL Logic Devices.)
Resource Reference of Application Notes AN1404 - ECLinPS Circuit Performance at Non-Standard VIH Levels
AN1405 AN1406 AN1503 AN1504 AN1568 AN1596 AN1650 AN1672 AND8001 AND8002 AND8020
- - - - - - - - - - -
ECL Clock Distribution Techniques Designing with PECL (ECL at +5.0 V) ECLinPS I/O SPICE Modeling Kit Metastability and the ECLinPS Family Interfacing Between LVDS and ECL ECLinPS Lite Translator ELT Family SPICE I/O Model Kit Using Wire-OR Ties in ECLinPS Designs The ECL Translator Guide Odd Number Counters Design Marking and Date Codes Termination of ECL Logic Devices
http://onsemi.com
14
MC10E197
PACKAGE DIMENSIONS
PLCC-28 FN SUFFIX PLASTIC PLCC PACKAGE CASE 776-02 ISSUE E
B U
0.007 (0.180)
M
T L -M
M
S
N
S S
-N-
Y BRK D
0.007 (0.180)
T L -M
N
S
-L-
-M-
Z
W
V
D X VIEW D-D G1
0.010 (0.250)
S
T L -M
S
N
S
28
1
A
0.007 (0.180)
M
T L -M T L -M
S
N N
S
Z
H
0.007 (0.180)
M
T L -M
S
N
S
R
0.007 (0.180)
M
S
S
C G G1
0.010 (0.250)
E
0.004 (0.100)
K1
J
-T-
SEATING PLANE
K F VIEW S
0.007 (0.180)
VIEW S
M
T L -M
S
N
S
S
T L -M
S
N
S
NOTES: 1. DATUMS -L-, -M-, AND -N- DETERMINED WHERE TOP OF LEAD SHOULDER EXITS PLASTIC BODY AT MOLD PARTING LINE. 2. DIM G1, TRUE POSITION TO BE MEASURED AT DATUM -T-, SEATING PLANE. 3. DIM R AND U DO NOT INCLUDE MOLD FLASH. ALLOWABLE MOLD FLASH IS 0.010 (0.250) PER SIDE. 4. DIMENSIONING AND TOLERANCING PER ANSI Y14.5M, 1982. 5. CONTROLLING DIMENSION: INCH. 6. THE PACKAGE TOP MAY BE SMALLER THAN THE PACKAGE BOTTOM BY UP TO 0.012 (0.300). DIMENSIONS R AND U ARE DETERMINED AT THE OUTERMOST EXTREMES OF THE PLASTIC BODY EXCLUSIVE OF MOLD FLASH, TIE BAR BURRS, GATE BURRS AND INTERLEAD FLASH, BUT INCLUDING ANY MISMATCH BETWEEN THE TOP AND BOTTOM OF THE PLASTIC BODY. 7. DIMENSION H DOES NOT INCLUDE DAMBAR PROTRUSION OR INTRUSION. THE DAMBAR PROTRUSION(S) SHALL NOT CAUSE THE H DIMENSION TO BE GREATER THAN 0.037 (0.940). THE DAMBAR INTRUSION(S) SHALL NOT CAUSE THE H DIMENSION TO BE SMALLER THAN 0.025 (0.635).
DIM A B C E F G H J K R U V W X Y Z G1 K1
INCHES MIN MAX 0.485 0.495 0.485 0.495 0.165 0.180 0.090 0.110 0.013 0.019 0.050 BSC 0.026 0.032 0.020 0.025 0.450 0.456 0.450 0.456 0.042 0.048 0.042 0.048 0.042 0.056 0.020 2 10 0.410 0.430 0.040
MILLIMETERS MIN MAX 12.32 12.57 12.32 12.57 4.20 4.57 2.79 2.29 0.33 0.48 1.27 BSC 0.81 0.66 0.51 0.64 11.58 11.43 11.58 11.43 1.07 1.21 1.07 1.21 1.42 1.07 0.50 2 10 10.42 10.92 1.02
http://onsemi.com
15
MC10E197
ON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. "Typical" parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including "Typicals" must be validated for each customer application by customer's technical experts. SCILLC does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT: Literature Distribution Center for ON Semiconductor P.O. Box 5163, Denver, Colorado 80217 USA Phone: 303-675-2175 or 800-344-3860 Toll Free USA/Canada Fax: 303-675-2176 or 800-344-3867 Toll Free USA/Canada Email: orderlit@onsemi.com N. American Technical Support: 800-282-9855 Toll Free USA/Canada Europe, Middle East and Africa Technical Support: Phone: 421 33 790 2910 Japan Customer Focus Center Phone: 81-3-5773-3850 ON Semiconductor Website: www.onsemi.com Order Literature: http://www.onsemi.com/orderlit For additional information, please contact your local Sales Representative
http://onsemi.com
16
MC10E197/D


▲Up To Search▲   

 
Price & Availability of MC10E197FNR2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X